7
SPECIFICATIONS
Function Range
Resolution
Accuracy
Non-contact
AC voltage
detector
50 to
600V
NA
200mV 0.1mV
2.000V 1mV
20V 0.01V
200V 0.1V
DC Voltage
(V DC)
600V 1V
±(0.7% reading + 2 digits)
200mV 0.1V
2.000V 1mV
20V 0.01V
200V 0.1V
±(0.8% reading +3 digits
AC Voltage
(V AC)
(40-400Hz)
600V 1V
±(1.0% reading +3 digits
200Ω 0.1Ω ±(1.0% reading +3 digits)
2kΩ 0.001kΩ
20kΩ 0.01kΩ
200kΩ 0.1kΩ
2MΩ 0.001MΩ
±(1.0% reading +1 digit)
Resistance
(open circuit
voltage:
0.25V)
20MΩ 0.01MΩ ±(1.0% reading +5 digits)
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less
than 75% RH.
Diode Test: Forward DC bias Current: 1mA approx.;
Reverse DC bias voltage: 1.5V approx.
Overload protection: 250VDC or ACrms
Continuity Check Audible signal will sound if the
resistance is less than 50Ω
Open circuit voltage: 0.5V; Overload
protection: 250VDC or AC
Display 2000 count (0 to 1999) LCD
Input Impedance 10MΩ , AC & DC Voltage
Over-range indication ‘OL’ is displayed
Auto Power Off After 15 minutes (approx.) of inactivity