OPERATION I MAINTENANCE
.
There are conditions of deep well operation when
the regulator valve may be completely open with-
out any faltering of pressure. In this case, operate
pump with regulator valve open.
HELPFUL HINTS I MAINTENANCE
How To Handle A Gaseous Well
In some areas well water contains gases which must be
allowed to escape before the water is used. To deliver
gas-free water suspend a pipe, closed at the bottom and
open at the top, so that it surrounds the suction pipe
inlet. (See Figure 17). Since the gases rise in the well
casing, the water sucked down through the pipe and
into the suction pump is free of gas. This type of well
must be vented to the outside of any enclosure.
Air Control In Flowing Wells
Flowing wells or wells with little or no drawdown,
could create a special p__ti_ocitrol in the op-
eration of your standard tank system. In such cases, a
pre-charged tank (which needs no air control) is
recommended.
Using the Compound Gauge
If the pump or system seems to be operating ineffi-
ciently, the compound gauge can sometimes help de-
termine the problem.
A compound gauge is a combination vacuum and pres-
sure gauge which will indicate (1) receding water level
in the well, (2) leakage in the suction line or in the
pump, or (3) clogged impeller.
To use, install the gauge in the air volume control (AVC)
port in the base of the pump. Open all shutoff valves
between pump and household piping. Tighten regula-
tor screw as far as possible. After running pump a few
minutes to eliminate all air from pipes, loosen regula-
tor screw until compound gauge shows 15" of vacuum.
This setting indicates that the pressure regulator is set
for delivery of the highest volume of water possible.
Let the pump run a few minutes; if the water level in
the well is falling, the vacuum will increase. If neces-
sary, reduce the regulator setting to bring the vacuum
reading back to 15". If the pump does not develop 15"
of vacuum according the gauge, you may have air leaks
in the suction line or a clogged impeller.
Cleaning the Deep Well Jet
1. Disconnect power.
2. Disconnect piping and well seal or casing adapter.
3. Withdraw jet assembly from the well.
4. Unscrew and remove the venturi. Remove the noz-
zle with a socket wrench and clean.
5. Replace all parts, reprime, and turn on power.
Figure 16A - Open Regulator Valve
Gases
rise to
sudace
Figure 16B - Watch for Pressure Gauge to Flutter
wireto hold
pipesleeve
pipe
valve
sleeve
Figure 16C - Close Regulator Valve until
Pressure Stabilizes
cap
Figure 17 - Gas/Air Control in Well
11