Craftsman 390.251883 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Craftsman 390.251883. Craftsman 390.251883 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SEARS
OWNER'S
MANUAL
MODEL NO.
390.251483
390.251883
CAUTION:
Read and Follow
All Safety Rules and
Operating Instructions
Before First Use of
This Product.
Save This Manual For
Future Reference.
CRflFTSMflN^
PROFESSIONAL
“HYDROGLASS”®
SHALLOW WELL JET PUMP
Safety Instructions
Installation
Operation
• Troubleshooting
Repair Parts
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A.
Form No. F642-9906 (Rev, 4/18/01)
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - CRflFTSMflN^

SEARSOWNER'SMANUALMODEL NO.390.251483 390.251883CAUTION:Read and Follow All Safety Rules and Operating Instructions Before First Use of This Prod

Page 2 - A WARNING

REPAIR PARTSKeyNo.1/2 HP Model 390.2514833/4 HP Model 390.251883PartDescriptionJ218-953C Motor -1/2 HP - 115/230V - 60 Cycle-J218-954CMotor - 3/4 HP -

Page 3 - MAJOR COMPONENTS / PIPING

REPAIR PARTS... ... " .ip'if- . i'^riMfA,' €¿/1 Oeiiteir. 'or .Sto№;11

Page 4

SEARSOWNER'SMANUALMODEL NO.390.251483390.251883The model number of your Shallow Well Jet Pump will be found on the pump body.When requesting serv

Page 5 - 3781 1000

READ AND FOLLOW SAFETY INSTRUCTIONS!AA DANGERA WARNINGA CAUTIONThis is the safety alert symbol. When you see this symbol on your pump or in this manua

Page 6 - INSTALLATION / OPERATION

CONTENTSSafety... 2W ananty/Introduction...

Page 7 - REPLACING SHAFT SEAL

MAJOR COMPONENTS / PIPINGPressure SwitchThe pressure switch provides automatic control.MODEL NO.PUMP STARTS ATPUMP STOPS AT390.25148340 PSI60 PSI390.2

Page 8 - HELPFUL HINTS

ELECTRICAL^ Disconnect power before working on pump, motor, pressure switch, or wiring.Your Motor Terminal Board (under the motor end cover)

Page 9 - TROUBLESHOOTING CHART

INSTALLATION / OPERATIONINSTALLATIONSEARS jet pumps should be used with Captive Air® Tanks (See Figure 5).SIDE VIEWFIGURE 5For mounting pump

Page 10 - REPAIR PARTS

SERVICEMAtNTAINING YOUR PUMPLubricationIt is not necessary to lubricate the pump or its motor. The motor bearings are lubricated for life. The

Page 11

SERVICEC. With finger pressure press seat firmly and squarely into cavity. See Figure lOA. Polished face of seat faces inside of pump. If seat wUI n

Page 12 - CRAFTSMAN^

TROUBLESHOOTING CHARTPROBLEM POSSIBLE CAUSES REMEDIESMotor will not run. 1. Disconnect switch is off. 1. Be sure .switch is on.2. Fuse is blown.2. Rep