Vue de la page 34
35
HAVING A PROBLEM?
NOTE: Always unplug BBU prior to troubleshooting
1. My door will not close and the light bulbs blink on
my motor unit: The safety reversing sensor must be
connected and aligned correctly before the garage
door opener will move in the down direction.
Verify the safety sensors are properly installed,
aligned and free of any obstructions. Refer to
Installation Step 10: Install The Protector System
®
.
Check diagnostic LED for flashes on the motor unit
then refer to the Diagnostic Chart on the following
page.
2. My remotes will not activate the door:
Verify your Motion Detecting Control Console is not
blinking. If it is blinking, deactivate the Lock Mode
following the instructions for Using the Motion
Detecting Control Console.
Reprogram remotes following the programming
instructions. Refer to Programming.
If remote will still not activate your door, check
diagnostic LED for flashes on motor unit then refer to
Diagnostic Chart on the following page.
3. The door reverses for no apparent reason and
opener lights don’t blink:
Is something obstructing the door? Pull the emergency
release handle. Operate the door manually. If it is
unbalanced or binding, call a trained door systems
technician.
Clear any ice or snow from the garage floor area
where the door closes.
Review Adjustment Step 2.
Repeat safety reverse test after adjustments.
4. The door reverses for no apparent reason and
opener lights blink for 5 seconds after reversing:
Check the safety reversing sensor. Remove any
obstruction or align the receiving eye. See Installation
Step 10.
5. My lights will not turn off when door is open:
The garage door opener is equipped with a security
light feature. This feature activates the light on when
the safety sensor beam has been obstructed. Refer
to Operation section; Using the Wall Mounted Door
Control, Light Feature.
Safety Reversing Sensor
Bell Wire
“Learn” Button LED
or Diagnostic LED
Receiving Eye Safety Reversing
Sensor (Green Indicator Light)
Sending Eye Safety Reversing
Sensor (Amber Indicator Light)
6. My motor unit hums briefly:
First verify that the trolley is against the stop bolt.
Release the door from the opener by pulling the
Emergency Release Rope.
Manually bring the door to a closed position.
Loosen the belt by adjusting the outer nut 4 to 5
turns. This relieves the tension.
Run the motor unit from the remote control or door
control. The trolley should travel towards the door
and stop. If the trolley re-engages with the door, pull
the Emergency Release Rope to disengage.
Decrease the UP travel.
Re-Tighten the outer nut until the trolley spring is
approximately 1-1/4" (3.18 cm) in length.
If the trolley does not move away from the bolt,
repeat the steps above.
1-1/4"
(3.18 cm)
Trolley